| Français |
| Toronto: 416 754 7008 |
| Montreal: 514 695 5147 |
| Canada: 1 888 754 7008 |
|
|
|
|
|
|
|
|
|
|
DIN Rail Mount
|
|
|
|
|
Inputs are available for TC's, Thermister, RTDs, LVDTs, Strain Gauge, 4-20ma, Analog Voltage, Frequency, etc.
Direct connection to Laptop PC's and/or connection through Wireless Communication and communication via CANbus, RS485, USB, Ethernet and Profibus are available with other devices, such as controllers, PLC's, PC's etc.
Mathematic functions, Adding, Subtracting, etc. as well as Control fuctions and Data Logging are available | | | | | | | | | | | | | | | | | | | | Datasheet | | | Interface/Features | | RS - 232/RS - 485 | | | | Models: 8B30-04, -05, -06, 8B31-04, -05, -06, 8B32-01, -02, 8B34-01, -02, -03, 8B35-01, -02, -03, 8B36-01, -02, -03... | | | | | | | - Input: Voltage, Current, Thermocouple, RTD, DC LVDT, Strain Gauge, Frequency, True RMS, Potentiometer
- Output: Raw Data, max/min, average, counter values..
- Interface: USB,RS232/485(Optional: WiFi,Bluetooth,Ethernet..)
- Housing: DIN rail | | | Datasheet | | | Input Type | | DC Current | | Strain Gauge | | RTD | | | | Models: 8BIR | | | | | | | | | | Models: 5D
, 5D30, 5D64, 5D70, 5D78 | | | | | | | | | | | Datasheet | | | Interface/Features | | RS - 232/RS - 485 | | | | Models: DCP35-P, DCP35-S | | | | | | | | | | | Datasheet | | | Interface/Features | | RS - 232/RS - 485 | | | | Models: DCP485-P, DCP485-S | | | | | | | - 1 or 4 universal analog inputs: Voltage, current, resistance, Potentiometer, Pt100, Pt1000, thermocouples, bridges
- Accuracy 0.01 %
- 19 bit ADC resolution
- 1000 Hz sample rate
- 1 digital input per channel: Status, tare, reset peak hold
- 1 solid state relay output per channel
Status, alarm, limit value, tolerance band
- Signal conditioning: Linearization, digital filtering, averaging, scaling, minimum/maximum, arithmetic, alarm
- RS 485 fieldbus interface: Profibus-DP, Modbus-RTU, ASCII as well as connectable to any
- 3 way isolation voltage 500 VDC
- Electromagnetic Compatibility according EN 61000-4 and EN 55011
- DIN rail mounting (EN500022) | | | Datasheet | | | Input Type | | DC Current | | Digital Inputs | | Strain Gauge | | | | Models: A1-1, A1-4 | | | | | | | - High accuracy: Deviation max. 0.05°C, Temperature influence 0.025°C
- 2, 3, or 6 input channels
2 input channels for Pt100/Pt1000 in 4
3 input channels for Pt100/Pt1000 in 3
6 input channels for Pt100/Pt1000 in 2
- High accuracy digitalization: 19 bit ADC, 10 Hz sampling rate per channel
- Signal conditioning: linearization, digital filtering, averaging, minimum/maximum, arithmetic, alarm
- 1 digital input and 1 digital output:
Status, tare, reset peak hold
Status, alarm, limit value, tolerance band
- RS 485 fieldbus interface: Profibus-DP, Modbus-RTU, ASCII as well as connectable to any
- Galvanic isolation: I/O-signals, power supply and interface
Isolation voltage 500 VDC
- Electromagnetic Compatibility according EN 61000-4 and EN 55011
- Power supply 10…30 VDC | | | | Models: ebloxx A5 | | | | | | | - 2 input channels for Cryo sensors e.g. Cernox or TVO
- Sensor excitation of 8 μAeff / 5 μAeff only: Avoids self heading of the sensor
- Individual linearization of the sensor characteristics: Sensor specific linearization by using 64 nodes and archive in a sensor data file. Import of manufacturers calibration data
- High accuracy digitalization: 19 bit ADC, 10 Hz sampling rate per channel
- Signal conditioning. Digital filtering, averaging, minimum/maximum, arithmetic, alarm
- 1 digital input and 1 digital output: Status, tare, reset peak hold. Status, alarm, limit value, tolerance band
- RS 485 fieldbus interface: Profibus-DP, Modbus-RTU, ASCII as well as connectable to any
- Galvanic isolation of I/O-signals, power supply and interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN500022) | | | | Models: ebloxx A5CR 2 | | | | | | | - Accuracy 0.05
- Universal bridge input: Strain gauge full, half, and quarter, inductive bridges, LVDT,
etc. Supports 3, 4, 5, and 6 lead connection (excitation sense), wide measuring range 2.5 to 1250 mV/V
- High accuracy digitalization: 19 bit ADC, 5000 Hz sampling rate
- 2 analog outputs: ± 10 V, user configurable (e.g. maximum, envelope curve, etc.)
- 6 digital input and 4 digital output: Status, tare, reset peak hold, counter, frequency measurement. Status, alarm, limit value, tolerance band
- Signal conditioning: Linearization, digital filtering, averaging, scaling, min
mum/maximum, run/hold, envelope curve, arithmetic, alarm
- RS 485 fieldbus interface: Profibus-DP, Modbus-RTU, ASCII as well as connectable to any e.series Test Controller
- Galvanic isolation of I/O-signals, power supply and interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN500022) | | | | Models: ebloxx A6-2CF | | | | | | | Most important features
- Accuracy 0.02 %
- 4 analog output channels: Selectable voltage (±10 V) or current (0 to 20 mA)
- High accuracy digitalization: 19 bit ADC, 10 Hz sampling rate per channel
- Signal conditioning: Additional scaling, minimum/maximum, arithmetic, alarm
- 1 digital input and 1 digital output: Status, reset peak hold, alarm, limit value, tolerance band
- RS 485 fieldbus interface: Profibus-DP, Modbus-RTU, ASCII as well as connectable to any e.series Test Controller
- Galvanic isolation of I/O-signals, power supply and interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN500022) | | | | Models: ebloxx A9 | | | | | | | - 8 or 32 configurable digital inputs / outputs
- Status in/outputs: Process or host controlled
(each I/O can be configured as IN or OUT)
- Frequency in/outputs: Frequency measurement up to 2 MHz, frequency output up to 10 kHz
- Counter inputs: Quadrature counter, up/down counter, up to 400 kHz
- PWM in/outputs, time measurement: Measurement of duty cycle and frequency
- Signal conditioning: Additional scaling, minimum/maximum, arithmetic, alarm
- RS 485 fieldbus interface: Profibus-DP, Modbus-RTU, ASCII as well as connectable to any e.series Test Controller
- Galvanic isolation of I/O-signals, power supply and interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN500022) | | | | Models: ebloxx D1 | | | | | | | | | | | | | Models: ebloxx D1, ebloxx D2, ebloxx D3 | | | | | | | - Inputs: Vdc, mV, mA, RTD, TC, Strain Gauge,
- LVDT, Piezo, Potentiometer, Frequency
- Outputs: +/-10Vdc, 0/4-20mA, digital I/O
- Communication: Profibus, Modbus, Ethernet, RS232/485
- Power: 10-30Vdc
- Programmable Functions, Linearization, Max/Min, Limits | | | Datasheet | | | Inputs | | Analog - DC | | Analog - AC | | Current | | | | Models: ebloxx, ebloxxA1, ebloxxA3, ebloxxA4, ebloxxA5, ebloxxA6... | | | | | | | | | | Models: egate IP DP EC CO | | | | | | | - Extensive function block library: Sequences, data archive, PID-controller and further transfer functions, mathematic, numeric, boolean combinations, function generator
- Data memory 16 Mbytes (DL-version 128 Mbytes Flash): Configurable memory for measurements, I/Os and conditioned variables
- Synchronizing: Data acquisition and PAC functionality up to 1 kHz
- Open file structure: Total integration in OEM automation systems, access to all configuration parameters and variables via text files and FTP
- Different interfaces: Ethernet TCP/IP (all versions), Profibus-DP (DP-version), EtherCAT (EC-version), CANopen (CO version), USB Host (DL-version)
- Galvanic isolation of I/O-signals, power supply, and communication interface
- Electromagnetic compatibility: according to EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (DIN EN 50022 rail) | | | | Models: epacCO, epacDL, epacDP, epacEC, epacIP | | | | | | | | | | | Datasheet | | | Input Type | | DC Current | | Digital Inputs | | Strain Gauge | | | | Models: ISM
, ISM103
, ISM108
, ISM111
, ISM112
| | | | | | | | | | Models: LDM30-P, LDM30-PE, LDM30-PT, LDM30-S, LDM30-SE, LDM30-ST... | | | | | | | | | | | Datasheet | | | Interface/Features | | RS - 232/RS - 485 | | | | Models: LDM35-P, LDM35-S | | | | | | | | | | Models: LDM70-P, LDM70-PE, LDM70-PT, LDM70-S, LDM70-SE, LDM70-ST... | | | | | | | | | | | Datasheet | | | Interface/Features | | RS - 232/RS - 485 | | | | Models: LDM85-P, LDM85-PE, LDM85-PT, LDM85-S, LDM85-SE, LDM85-ST... | | | | | | | | | | Models: MAQ20-BKL8, MAQ20-BKPL16, MAQ20-BKPL24, MAQ20-BKPL4, MAQ20-BRDG1, MAQ20-COM2... | | | | | | | - 2 universal analog input channels: voltage, current, resistance, potentiometer, Pt100, Pt1000, thermocouples, measuring bridges, IEPE sensors
- Fast high accuracy digitalization: 24 bit ADC, 100 kHz sample rate per channel
- 1 digital in or output per channel:
input: state, tare, memory reset
output: state, alarm, threshold
- Signal conditioning: 16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm
- TEDS: class 1 and class 2, according IEEE 1541.4
- RS485 fieldbus interface: up to 48 Mbps: LocalBus, and up to 115.2 kbps: Modbus-RTU, ASCII
- Connectable to any Test Controller: e.g. Q.gate or Q.pac
- Galvanic isolation: channel to channel to power supply and to interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | Datasheet | | | Input | | DC Voltage | | DC Current | | Digital | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | - 8 x Galvanic isolated input channels
- Differential voltage, current via shunt connector
- Isolation voltage 100 VDC
- High accuracy digitalization
- 24 bit ADU, 100 Hz sample rate per channel with 8 active channels, sum sample rate 800 Hz
- 2 digital input: state, tare, memory reset
- digital output: state alarm, thresh hold
- Signal conditioning: Linearization, digital filter, average, scaling, min/max storage, arithmetic, alarm
- RS485 fieldbus-interface up to 48 Mbps: LocalBus
- up to 115.2 kbps: Modbus-RTU, ASCII
- Connectable to any Test Q.gate or Q.pac
- Galvanic isolation of I/O-signals, power supply and interface Isolation voltage 500 VDC
- Accuracy class 0.01
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | - 8 galvanic isolated input channels thermocouples and voltages in the range of ± 80 mV. Isolation voltage 100 VDC
- Cold junction compensation: good thermal coupling by means of cold junction compensation
per connector
- Dynamic linearization: optimized positioning of the interpolation points within the selected range, type B, E, J, K, L N, R, S, T, U
- High accuracy digitalization: 24 bit ADC, 100 Hz sample rate per channel, sum sample rate 800 Hz
- Signal conditioning: digital filter, average, scaling, min/max storage, arithmetic, alarm
- RS485 fieldbus-interface:
up to 48 Mbps: LocalBus
up to 115.2 kbps: Modbus-RTU, ASCII
- Connectable to any Test Controller: e.g. Q.gate or Q.pac
- Galvanic isolation: channels to power supply and to interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Accuracy class 0,01
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | - 4 universal analog input channels: voltage, current, resistance, potentiometer, Pt100, Pt1000, thermocouples, measuring bridges
- Fast high accuracy digitalization: 24 bit ADC, 10 kHz sample rate per channel
- Signal conditioning: 16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm
- RS485 fieldbus interface:
up to 48 Mbps: LocalBus
up to 115.2 kbps: Modbus-RTU, ASCII
- Connectable to any Test Controller: e.g. Q.gate or Q.pac
- Galvanic isolation: channel to channel to power supply and to interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | Datasheet | | | Input | | DC Voltage | | DC Current | | Digital | | | | Models: A102, A104, A108, A109, D101, Q bloxx A106... | | | | | | | - 8 galvanic isolated input channels: differential voltage, current via shunt connector; Isolation voltage 500 VDC
- Fast and high accuracy digitalization: 24 bit ADC, 10 kHz sample rate per channel with 8 active channels
- 2 digital in and 2 outputs:
input: state, tare, memory reset
output: state, alarm, threshold
- Signal conditioning: linearization, digital filter, average, scaling,
min/max storage, RMS, arithmetic, alarm
- RS485 fieldbus-interface:
up to 48 Mbps: LocalBus
up to 115,2 kbps: Modbus-RTU, ASCII
- Connectable to any Test Controller: e.g. Q.gate or Q.pac
- Galvanic isolation: channel to channel to power supply and to interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Accuracy class 0,01
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022 rail) | | | Datasheet | | | Input | | DC Voltage | | Digital | | Thermocouple | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | - 4 galvanic isolated analog output channels voltage ±10 V, current 0…20 mA selectable; Isolation voltage 500 VDC permanent
- DAC-resolution 16 bit: 100 kHz each channels
- 4 digital inputs and 4 digital outputs: Configurable as 2 counter, 2 frequency, or 2 PWM inputs, 4 frequency out, 4 PWM output, or 4 state out
- Frequency in and outputs: frequency measurement up to 1 MHz (Chronos method), frequency output up to 10 kHz
- Counter: For/backward counter, quadrature counter with reference zero recognition (reset/enable), up to 1 MHz
- PWM in and output: measurement of duty cycle and frequency, output with variable
frequency and/or duty cycle
- Outputs freely scalable
- RS485 fieldbus-interface: up to 48 Mbps: LocalBus, up to 115.2 kbps: Modbus-RTU, ASCII
- Galvanic isolation: I/O-signals to power supply and to interface. Isolation voltage 500 VDC
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | Datasheet | | | Inputs | | Analog - DC | | Analog - AC | | Digital | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | - 4 high galvanic isolated input channels differential voltage, current via shunt connector, isolation voltage 1200 VDC permanenT
- 3 measuring ranges selectable each channel: ±10 V, ±1.25 V, ±100 mV
- Fast high accuracy digitalization: 24 bit ADC, 10 kHz sample rate per channel
- Signal conditioning: linearization, digital filter, average, scaling, min/max storage, arithmetic, alarm
- RS485 fieldbus interface:
Up to 48 Mbps: LocalBus
Up to 115.2 kbps: Modbus-RTU, ASCII
- Connectable to any Test Controller e.g. Q.gate or Q.pac
- Galvanic isolation: channel to channel to power supply and to interface isolation voltage 1200 VDC / 858 VACrms. Test voltage 5 kVrms over 1 minute
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | - 4 high galvanic isolated input channels thermocouple on high voltage potential (not isolated), isolation voltage 1200 VDC permanent
- Cold junction compensation: each channel on board
- Dynamic linearization: optimized positioning of the interpolation points within the selected range, type B, E, J, K, L N, R, S, T, U
- Fast high accuracy digitalization: 24 bit ADC, 10 kHz sample rate per channel
- Signal conditioning: linearization, digital filter, average, scaling, min/max storage, arithmetic, alarm
- RS485 fieldbus interface:
Up to 48 Mbps: LocalBus
Up to 115.2 kbps: Modbus-RTU, ASCII
- Connectable to any Test Controller e.g. Q.gate or Q.pac
- Galvanic isolation: channel to channel to power supply and to interface
isolation voltage 1200 VDC / 858 VACrms, test voltage 5 kVrms over 1 minute
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | - 4 high galvanic isolated input channels differential voltage, isolation voltage 1200 VDC permanent
- 4 measuring ranges selectable each channel: ±40 V; ±120 V, ±400 V, ±1200 V
- Fast high accuracy digitalization: 24 bit ADC, 50 kHz sample rate per channel with 4 active channels, 100 kHz sample rate per channel with 2 active channels
- Signal conditioning: linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm
- RS485 fieldbus interface:
Up to 48 Mbps: LocalBus
Up to 115.2 kbps: Modbus-RTU, ASCII
- Connectable to any Test Controller e.g. Q.gate or Q.pac
- Galvanic isolation: channel to channel to power supply and to interface. Isolation voltage 1200 VDC / 858 VACrms. Test voltage 5 kVrms over 1 minute.
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | | Models: Q bloxx A101, Q bloxx A102, Q bloxx A103, Q bloxx A104, Q bloxx A106, Q bloxx A107... | | | | | | | | | | Models: Q bloxx D101, Q bloxx D104, Q bloxx D105 | | | | | | | | | | Models: Q bloxx D101, Q bloxx D104, Q bloxx D105 | | | | | | | | | | Models: Q bloxx D101, Q bloxx D104, Q bloxx D105 | | | | | | | System Features
- High density and flexibility: up to 16 modules in one system in any constellation,
flexible plug selection
- Test Controller inclusive: Ethernet TCP/IP for configuration and data transfer, 16 MByte data memory, expandable by USB device, logging features, PAC functionality, IRIG synchronization
- Robust and reliable: stable and compact aluminum housing, easy to carry electromagnetic compatibility according EN 61000-4 and EN 55011. Temperature range -20 up to +60°C and power supply 10 up to 30 VDC
Features of the module A101
- 2 universal analog input channels: voltage, current, resistance, potentiometer, Pt100, Pt1000, thermocouples, full and half bridges, IEPE-sensors
- Fast high accuracy digitalization: 24 bit ADC, 100 kHz sample rate per channel
- 1 digital in or output per channel
input: state, tare, memory reset, alarm threshold
output: state alarm, threshold
- Signal conditioning: virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm
- TEDS: class 1 and class 2, according IEEE 1541.4
- Galvanic isolation: channel to channel to power supply and to interface, Viso 500 VDC | | | Datasheet | | | Input | | DC Voltage | | DC Current | | Digital | | | | Models: Q brixx A101, Q brixx A102, Q brixx A103, Q brixx A104, Q brixx A106, Q brixx A107... | | | | | | | - Connection of up to 32 Q.bloxx modules: via 2 UARTS, Baud rate up to 24 MBaud each UART. Recording of up to 256 variables (real format 4 Byte)
- Synchronization and time stamp of measurement values. IRIG based master slave principle on RS485 standard. DCF77, AFNOR etc, GPS time and position data, SNTP over Ethernet
- Ethernet interface for configuration and data output: FTP, TCP/IP, UDP
optional fieldbus interface Profibus-DP, 12 Mbps
- FTP Server and FTP Client functionality: configurable function
- High data rate over Ethernet:
128 real variables with 1 kHz (block transfer)
16 real variables with 10 kHz (block transfer)
64 real variables with 300 Hz (online)
- Data buffer memory 16 MByte: Data buffer at block transfer of measurements, different logger possibilities, extendable by USB device
- PAC functionality: Sequences, data logger, PID-controller, transfer functions, mathematic, numeric, Boolean combinations, functions generator
- Galvanic isolation of power supply and interfaces
- Electromagnetic Compatibility: according EN 61000-4 and EN 55011
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | Datasheet | | | Interface/Features | | Ethernet | | RS - 232/RS - 485 | | USB | | | | Models: Q gate | | | | | | | - Connection of up to 64 Q.bloxx modules via 4 UARTS, Baud rate up to 24 MBaud each UART. Recording of up to 256 variables (real format 4 Byte)
- Synchronization and time stamp of measurement values: IRIG based master slave principle on RS485 standard. DCF77, AFNOR etc, GPS time and position data, SNTP over Ethernet
- Ethernet interface for configuration and data output: FTP, TCP/IP, UDP
- FTP Server and FTP Client functionality: configurable function
- Optional fieldbus interface EtherCAT: EtherCAT according specification ETG, 256 read and 256 write variable with 10 kHz
- High data rate over Ethernet:
128 real variables with 1 kHz (block transfer)
16 real variables with 10 kHz (block transfer)
64 real variables with 300 Hz (online)
- Data buffer memory dyn. 16 MByte (RAM), stat. 128 MByte (flash): Data buffer at block transfer of measurements
- Mathematic, controlling and combination functionality
- PAC functionality with extensive function block library: Sequences, data logger, PID-controller, transfer functions, mathematic, numeric, Boolean combinations, functions generator
- Galvanic isolation of power supply and interfaces
- Power supply 10…30 VDC
- DIN rail mounting (EN 50022) | | | Datasheet | | | Interface/Features | | Ethernet | | RS - 232/RS - 485 | | USB | | | | Models: Q pac | | | |
|
|
|
|
|
|
|
|
|
|
|
|
|