GM62, 2 channel DIN Strain Gage Amplifier


- 10...30 V DC Supply, Galvanic Separation
- For Switch-Cabinet Assembly, Width 23 mm only
- Sensor Excitation 6...10 V adjustable
- Voltage Output 0...+/-10 V
- 2 Parallel Sensor Connections
- Direct Connection to PLC
- External Control
- Very Easy Operation
- Abatable Clamps
- DIN Rail Mount
- Rating: IP 21
forming to standards. The slim-line housing allows space saving assembly in switch-cabinets close to the sensors on standardized DIN mounting rails. A galvanically separated supply voltage range of 10...30 V and the analog output of 0...±10 V allow the direct signal processing with a PLC-control. All control elements are accessible front sided behind a hinged plexiglass pane. The adaptation of the sensor sensitivity takes place on site by a DIL-switch. Preloads (tare) can be adjusted. The control switch can be activated via an external control signal or via the front-sided control key. Interference signals and transient effects of the measurement signals can be alleviated by the input filter. The vernier of amplification, zero point and filter is possible by potentiometers.
Input Type | Strain Gauge |
# of Inputs | 2 |
Output Type | ±10 V DC |
Max Bandwidth | 1 kHz |
Excitation | 6 - 10 V DC |
Isolation | Yes |
Supply Power | 10 - 30 V DC |
IP Rating | IP 21 |
GM62, DIN SG Meauring Amplifier Datasheet |