3433A1, Low Bias Triaxial Accelerometer


- Low-power Triaxial Accelerometer
- 5 mV/g sensitivity
- 300g range
- 1 to 3,500 Hz frequency range (±10%)
- 4-pin 1/4-28 radial connector
- 10-32 tapped hole
- Case isolated
- Operates from +1.5 to +3.0 VDC
- IEPE
- Low Bias Voltage
- Maximum Vibration: 300 G
- Maximum Shock: 5000 G
- Linearity; 1.0% - best fit between any two points used for calibration
- Weight: 14 grams
- Titanium
- Hermetically sealed
The Dytran model 3433A1 is a low power, triaxial IEPE accelerometer with a 5 mV/g sensitivity and an overall weight of 14 grams. Featuring a bias voltage from +1.5 to +3.0 VDC, the Dytran model 3433A1 was designed for low turn-on voltage applications where power supply is limited. Sensors developed for such applications must be able to deliver accurate and reliable data while simultaneously tolerating harsh conditions. Critical characteristics of these sensors include a low-profile design, broad operating temperature, and the ability to operate at low power levels. The Dytran model 3433A1 is ideal for such applications, as it is packaged in a lightweight titanium housing with a vertical height of 0.54-inches (13.7-millimeters).
The Dytran model 3433A is designed with 10-32 stud mounting capabilities and a 4-pin 1/4-28 radial connector. Units are case isolated to avoid EMI/ground loop interference and are hermetically sealed for reliable operation in high humidity and dirty environments.
Supplied Accessories: (1) model 6200 mounting stud (10-32 to 10-32)
Recommended Accessories: model 4114B1 current source power unit, model 6196 magnetic mounting base, model 6213 adhesive mounting base
Compatible Cables: 6811A, 6812A, 6824A, 6828A, 6873A, 6925A, 6933A, 6967A, 6997A
Type | Voltage Mode (IEPE) |
# of Axis | 3 |
Full Scale | 300 g |
Output | 5 mV/g |
Excitation | 6 - 9 V DC |
Material | Titanium |
Mounting | 10-32 Tapped Hole |
Connection | 4-Pin Radial Connector |
Min Temperature | -51 °C |
Max Temperature | 121 °C |
3433A1 Datasheet Datasheet |
- IEPE
- Triaxial
- 5 mV/g or 10 mV/g sensitivity
- 500g or 1000g range
- 2 to 5,000 Hz frequency range (±10%)
- 4-pin 1/4-28 radial connector
- Adhesive mount
- Weight 5.5 grams
Type | Voltage Mode (IEPE) |
# of Axis | 3 |
Full Scale | 500 g, 1000 g |
Output | 5 mV/g, 10 mV/g |
Excitation | 18 - 30 V DC |
Material | Titanium |
- Triaxial
- IEPE
- Lightweight
- Miniature
- 1 mV/g, 5 mV/g, 10 mV/g sensitivity
- 500g, 1000g, 5000g range
- 1.5 to 10,000 Hz frequency range (+15/-5%)
- Axis 1 & 2: 1.5 to 4,000 Hz frequency range (+5%)
Type | Voltage Mode (IEPE) |
# of Axis | 3 |
Full Scale | 500 g, 1000 g, 5000 g |
Output | 1 mV/g, 5 mV/g, 10 mV/g |
Excitation | 18 - 30 V DC |
Material | Titanium |
- IEPE
- Triaxial
- Miniature design
- Broad frequency response
- 1 mV/g, 5 mV/g, or 10 mV/g sensitivity available
- 500g, 100g or 5,000g range
- 1.2 to 10,000 Hz frequency range (±15%)
- 4-pin 1/4-28 radial connector
Type | Voltage Mode (IEPE) |
# of Axis | 3 |
Full Scale | 500 g, 1000 g, 5000 g |
Output | 1 mV/g, 5 mV/g, 10 mV/g |
Excitation | 18 - 30 V DC |
Material | Titanium |
- IEPE
- Triaxial
- Lightweight
- Miniature
- +320°F (+160°C) operation (A2H,A6H)
- +325°F (+163°C) operation (AH,A3H,A4H))
- 1 mV/g, 5 mV/g, 10 mV/g sensitivity
- 500g, 1000g, 5000g range
Type | Voltage Mode (IEPE) |
# of Axis | 3 |
Full Scale | 500 g, 1000 g, 5000 g |
Output | 1 mV/g, 5 mV/g, 10 mV/g |
Excitation | 18 - 30 V DC |
Material | Titanium |
- Triaxial
- IEPE
- 10 mV/g sensitivity
- 500g range
- 1.1 to 5,000 Hz frequency range (±10%)
- 4-pin 1/4-28 radial connector
- 10-32 tapped hole
- Weight: 7.5 grams
Type | Voltage Mode (IEPE) |
# of Axis | 3 |
Full Scale | 500 g |
Output | 10 mV/g |
Excitation | 18 - 30 V DC |
Material | Titanium |