Loading...
A-Tech Instruments Ltd.
Français   |   Welcome. Please Register an Account or Login

DSCA38, Strain Gauge Input Analog Signal Conditioner DIN Rail Modules

The DSCA38 strain gauge input module provides a single channel of strain gauge input which is filtered, isolated, amplified and converted to a high-level voltage output.
DSCA38, Strain Gauge Input Analog Signal Conditioner DIN Rail Modules
DSCA38, Strain Gauge Input Analog Signal Conditioner DIN Rail Modules
Features:
  • Strain Gauge Input Module
  • 1500 V Transformer Isolation
  • True 3-Way Isolation
  • Accuracy: ± 0.03%
  • DIN Rail Mounted Module
  • ANSI/IEEE C37.90.1 Transient Protection
  • Input Protected to 240 V AC Continuous
Manufacturer:  Dataforth
Quote
Datasheet
Specifications
Models & Accessories
Downloads
Similar Products
DSCA38 - Specifications
Input TypeStrain Gauge
# of Inputs1
Output Type0 - 10 V DC
±10 V DC
0 - 20 mA
4 - 20 mA
Max Bandwidth3 kHz
Excitation3.33 V DC
10 V DC
IsolationYes
Supply Power19 - 29 V DC
DSCA38 - Models & Accessories
Models
DSCA38-01Full Bridge, ± 10 mV Input, ± 10 V DC Output
DSCA38-02Full Bridge, ± 30 mV Input, ± 10 V DC Output
DSCA38-03Half Bridge, ± 10 mV Input, ± 10 V DC Output
DSCA38-04Half Bridge, ± 30 mV Input, ± 10 V DC Output
DSCA38-05Full Bridge, ± 20 mV Input, ± 10 V DC Output
DSCA38-06Full Bridge, ± 33.3 mV Input, ± 10 V DC Output
DSCA38-07Full Bridge, ± 100 mV Input, ± 10 V DC Output
DSCA38-08Full Bridge, ± 10 mV Input, 0-10 V DC Output
DSCA38-09Full Bridge, ± 30 mV Input, 0-10 V DC Output
DSCA38-10Half Bridge, ± 10 mV Input, 0-10 V DC Output
DSCA38-11Half Bridge, ± 30 mV Input, 0-10 V DC Output
DSCA38-12Full Bridge, ± 20 mV Input, 0-10 V DC Output
DSCA38-13Full Bridge, ± 33.3 mV Input, 0-10 V DC Output
DSCA38-14Full Bridge, ± 100 mV Input, 0-10 V DC Output
DSCA38-15Full Bridge, 0-10 mV Input, 0-10 V DC Output
DSCA38-16Full Bridge, 0-30 mV Input, 0-10 V DC Output
DSCA38-17Half Bridge, 0-10 mV Input, 0-10 V DC Output
DSCA38-18Half Bridge, 0-30 mV Input, 0-10 V DC Output
DSCA38-19Full Bridge, 0-20 mV Input, 0-10 V DC Output
DSCA38-20Full Bridge, 0-33.3 mV Input, 0-10 V DC Output
DSCA38-21Full Bridge, 0-100 mV Input, 0-10 V DC Output
DSCA38-08CFull Bridge, ±10 mV Input, 4-20 mA Output
DSCA38-09CFull Bridge, ±30 mV Input, 4-20 mA Output
DSCA38-10CHalf Bridge, ±10 mV Input, 4-20 mA Output
DSCA38-11CHalf Bridge, ± 30 mV Input, 4-20 mA Output
DSCA38-12CFull Bridge, ± 20 mV Input, 4-20 mA Output
DSCA38-13CFull Bridge, ± 33.3 mV Input, 4-20 mA Output
DSCA38-14CFull Bridge, ± 100 mV Input, 4-20 mA Output
DSCA38-15CFull Bridge, 0-10 mV Input, 4-20 mA Output
DSCA38-16CFull Bridge, 0-30 mV Input, 4-20 mA Output
DSCA38-17CHalf Bridge, 0-10 mV Input, 4-20 mA Output
DSCA38-18CHalf Bridge, 0-30 mV Input, 4-20 mA Output
DSCA38-19CFull Bridge, 0-20 mV Input, 4-20 mA Output
DSCA38-20CFull Bridge, 0-33.3 mV Input, 4-20 mA Output
DSCA38-21CFull Bridge, 0-100 mV Input, 4-20 mA Output
DSCA38-08EFull Bridge, ± 10 mV Input, 0-20 mA Output
DSCA38-09EFull Bridge, ± 30 mV Input, 0-20 mA Output
DSCA38-10EHalf Bridge, ± 10 mV Input, 0-20 mA Output
DSCA38-11EHalf Bridge, ± 30 mV Input, 0-20 mA Output
DSCA38-12EFull Bridge, ± 20 mV Input, 0-20 mA Output
DSCA38-13EFull Bridge, ± 33.3 mV Input, 0-20 mA Output
DSCA38-14EFull Bridge, ± 100 mV Input, 0-20 mA Output
DSCA38-15EFull Bridge, 0-10 mV Input, 0-20 mA Output
DSCA38-16EFull Bridge, 0-30 mV Input, 0-20 mA Output
DSCA38-17EHalf Bridge, 0-10 mV Input, 0-20 mA Output
DSCA38-18EHalf Bridge, 0-30 mV Input, 0-20 mA Output
DSCA38-19EFull Bridge, 0-20 mV Input, 0-20 mA Output
DSCA38-20EFull Bridge, 0-33.3 mV Input, 0-20 mA Output
DSCA38-21EFull Bridge, 0-100 mV Input, 0-20 mA Output
DSCA38 - Downloads
DSCA38 - Similar Products
  • Strain Gauge & Potentiometer Input Amplifier
  • 50 V Continuous Isolation
  • Accuracy: ± 0.05%
  • DIN Rail Mounted
  • In-Line Amplifier (Option)
  • Aluminum Housing
  • Protection Class: IP40
Input Type
0 - 10 mV DC,
0 - 100 mV DC,
0 - 1 V DC,
0 - 10 V DC,
±10 V DC,
Potentiometer,
Strain Gauge
# of Inputs
1
Output Type
±5 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Max Bandwidth
1 kHz,
4 kHz
Excitation
2.5 V DC,
5 V DC,
10 V DC
Isolation
Yes
  • High Accuracy
  • For Switch Cabinet Assembly, Width 23 mm, only
  • Direct Connection to PLC
  • Long Input Lead from GM 40 to Evaluation possible
  • Easy to operate
  • Voltage or Current Output
  • DIN Rail Mount
  • Rating: IP20
Input Type
Strain Gauge
# of Inputs
1
Output Type
±5 V DC,
±10 V DC,
4 - 20 mA
Max Bandwidth
1 kHz,
5 kHz,
10 kHz
Excitation
5 V DC,
10 V DC
Isolation
Yes
  • DIN rail mounting Amplifier, Strain Gauge Transducer Amplifier
  • Compatible with most full bridge strain gauge transducers
  • Provide variable excitation and signal amplification
  • Screw terminal connections
  • Simple controls for gain and zero adjustment
  • Input zero switch
  • Continuous variation of excitation
  • Input/output isolation
Input Type
Strain Gauge
# of Inputs
1
Output Type
0 - 10 V DC,
±10 V DC,
4 - 20 mA
Max Bandwidth
5 kHz
Isolation
Yes
Supply Power
9 - 36 V DC
  • Voltage Input Module
  • 1500 V Transformer Isolation
  • True 3-Way Isolation
  • Accuracy: ± 0.03%
  • DIN Rail Mounted Module
  • ANSI/IEEE C37.90.1 Transient Protection
  • Input Protected to 240 V AC Continuous
Input Type
±1 V DC,
±2 V DC,
±3 V DC,
±4 V DC,
±5 V DC,
±6 V DC,
±7 V DC,
±8 V DC,
±9 V DC,
±10 V DC
# of Inputs
1
Output Type
0 - 10 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Max Bandwidth
3 kHz
Excitation
10 V DC
Isolation
Yes
  • Transmitter for strain gauge
  • Isolated Versions Available
  • USB Connectivity for easy calibration
  • DAQ Mode with a measuring rate - up to 7500 measurements per second
  • 2 Button teach-in for Potentiometer
  • Teach-in, allows easy setting of both min. and max. of the measuring range
  • Output: 4…20 mA/0…10 V
  • Power supply 18…30 VDC
Interface
USB
Input Type
Strain Gauge
# of Inputs
1
Output Type
0 - 10 V DC,
4 - 20 mA,
RS-485
Excitation
10 V DC
Isolation
Yes
Products    |    Applications    |    Services    |    Partners    |    About Us    |    Contact Us