DSCA38, Strain Gauge Input Analog Signal Conditioner DIN Rail Modules
- Strain Gauge Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | Strain Gauge |
# of Inputs | 1 |
Output Type | 0 - 10 V DC |
±10 V DC | |
0 - 20 mA | |
4 - 20 mA | |
Max Bandwidth | 3 kHz |
Excitation | 3.33 V DC |
10 V DC | |
Isolation | Yes |
Supply Power | 19 - 29 V DC |
DSCA38-01 | Full Bridge, ± 10 mV Input, ± 10 V DC Output |
DSCA38-02 | Full Bridge, ± 30 mV Input, ± 10 V DC Output |
DSCA38-03 | Half Bridge, ± 10 mV Input, ± 10 V DC Output |
DSCA38-04 | Half Bridge, ± 30 mV Input, ± 10 V DC Output |
DSCA38-05 | Full Bridge, ± 20 mV Input, ± 10 V DC Output |
DSCA38-06 | Full Bridge, ± 33.3 mV Input, ± 10 V DC Output |
DSCA38-07 | Full Bridge, ± 100 mV Input, ± 10 V DC Output |
DSCA38-08 | Full Bridge, ± 10 mV Input, 0-10 V DC Output |
DSCA38-09 | Full Bridge, ± 30 mV Input, 0-10 V DC Output |
DSCA38-10 | Half Bridge, ± 10 mV Input, 0-10 V DC Output |
DSCA38-11 | Half Bridge, ± 30 mV Input, 0-10 V DC Output |
DSCA38-12 | Full Bridge, ± 20 mV Input, 0-10 V DC Output |
DSCA38-13 | Full Bridge, ± 33.3 mV Input, 0-10 V DC Output |
DSCA38-14 | Full Bridge, ± 100 mV Input, 0-10 V DC Output |
DSCA38-15 | Full Bridge, 0-10 mV Input, 0-10 V DC Output |
DSCA38-16 | Full Bridge, 0-30 mV Input, 0-10 V DC Output |
DSCA38-17 | Half Bridge, 0-10 mV Input, 0-10 V DC Output |
DSCA38-18 | Half Bridge, 0-30 mV Input, 0-10 V DC Output |
DSCA38-19 | Full Bridge, 0-20 mV Input, 0-10 V DC Output |
DSCA38-20 | Full Bridge, 0-33.3 mV Input, 0-10 V DC Output |
DSCA38-21 | Full Bridge, 0-100 mV Input, 0-10 V DC Output |
DSCA38-08C | Full Bridge, ±10 mV Input, 4-20 mA Output |
DSCA38-09C | Full Bridge, ±30 mV Input, 4-20 mA Output |
DSCA38-10C | Half Bridge, ±10 mV Input, 4-20 mA Output |
DSCA38-11C | Half Bridge, ± 30 mV Input, 4-20 mA Output |
DSCA38-12C | Full Bridge, ± 20 mV Input, 4-20 mA Output |
DSCA38-13C | Full Bridge, ± 33.3 mV Input, 4-20 mA Output |
DSCA38-14C | Full Bridge, ± 100 mV Input, 4-20 mA Output |
DSCA38-15C | Full Bridge, 0-10 mV Input, 4-20 mA Output |
DSCA38-16C | Full Bridge, 0-30 mV Input, 4-20 mA Output |
DSCA38-17C | Half Bridge, 0-10 mV Input, 4-20 mA Output |
DSCA38-18C | Half Bridge, 0-30 mV Input, 4-20 mA Output |
DSCA38-19C | Full Bridge, 0-20 mV Input, 4-20 mA Output |
DSCA38-20C | Full Bridge, 0-33.3 mV Input, 4-20 mA Output |
DSCA38-21C | Full Bridge, 0-100 mV Input, 4-20 mA Output |
DSCA38-08E | Full Bridge, ± 10 mV Input, 0-20 mA Output |
DSCA38-09E | Full Bridge, ± 30 mV Input, 0-20 mA Output |
DSCA38-10E | Half Bridge, ± 10 mV Input, 0-20 mA Output |
DSCA38-11E | Half Bridge, ± 30 mV Input, 0-20 mA Output |
DSCA38-12E | Full Bridge, ± 20 mV Input, 0-20 mA Output |
DSCA38-13E | Full Bridge, ± 33.3 mV Input, 0-20 mA Output |
DSCA38-14E | Full Bridge, ± 100 mV Input, 0-20 mA Output |
DSCA38-15E | Full Bridge, 0-10 mV Input, 0-20 mA Output |
DSCA38-16E | Full Bridge, 0-30 mV Input, 0-20 mA Output |
DSCA38-17E | Half Bridge, 0-10 mV Input, 0-20 mA Output |
DSCA38-18E | Half Bridge, 0-30 mV Input, 0-20 mA Output |
DSCA38-19E | Full Bridge, 0-20 mV Input, 0-20 mA Output |
DSCA38-20E | Full Bridge, 0-33.3 mV Input, 0-20 mA Output |
DSCA38-21E | Full Bridge, 0-100 mV Input, 0-20 mA Output |
DSCA38 V2 Datasheet |
DSCA38 Datasheet |
DSCA Series Datasheet |
DSCA Dimensions Drawings |
DSCA Calibration Procedure App Note |
Sample Test Report Tech Note |
AN101 RMS_Voltage_Current App Note |
AN105 Resistance Temperature Detector V2 App Note |
AN121 RiseTime vs BW App Note |
AN126 Tuning_Surge_Tank_Level_Control_Loops App Note |
AN128 RMS Revisited App Note |
AN129 Harmonics and utility costs App Note |
AN801 DSCA Calibration Procedure App Note |
Hysteresis Specifications Tech Note |
Faraday's Law of Induction Tech Note |
Data Acquisition Systems Accessories Tech Note |
Signal Conditioner Surge Withstand Capability Tech Note |
Signal-to-Noise Ratio, SNR Tech Note |
Signal Conditioning Measured vs Combinational Error Tech Note |
When Good Grounds Go Bad Tech Note |
Why Isolation (White Paper) Tech Note |
Why Should Sensors Be Isolated Tech Note |
- Strain Gauge & Potentiometer Input Amplifier
- 50 V Continuous Isolation
- Accuracy: ± 0.05%
- DIN Rail Mounted
- In-Line Amplifier (Option)
- Aluminum Housing
- Protection Class: IP40
Input Type | 0 - 10 mV DC, 0 - 100 mV DC, 0 - 1 V DC, 0 - 10 V DC, ±10 V DC, Potentiometer, Strain Gauge |
# of Inputs | 1 |
Output Type | ±5 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 1 kHz, 4 kHz |
Excitation | 2.5 V DC, 5 V DC, 10 V DC |
Isolation | Yes |
- High Accuracy
- For Switch Cabinet Assembly, Width 23 mm, only
- Direct Connection to PLC
- Long Input Lead from GM 40 to Evaluation possible
- Easy to operate
- Voltage or Current Output
- DIN Rail Mount
- Rating: IP20
Input Type | Strain Gauge |
# of Inputs | 1 |
Output Type | ±5 V DC, ±10 V DC, 4 - 20 mA |
Max Bandwidth | 1 kHz, 5 kHz, 10 kHz |
Excitation | 5 V DC, 10 V DC |
Isolation | Yes |
- DIN rail mounting Amplifier, Strain Gauge Transducer Amplifier
- Compatible with most full bridge strain gauge transducers
- Provide variable excitation and signal amplification
- Screw terminal connections
- Simple controls for gain and zero adjustment
- Input zero switch
- Continuous variation of excitation
- Input/output isolation
Input Type | Strain Gauge |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, ±10 V DC, 4 - 20 mA |
Max Bandwidth | 5 kHz |
Isolation | Yes |
Supply Power | 9 - 36 V DC |
- Voltage Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | ±1 V DC, ±2 V DC, ±3 V DC, ±4 V DC, ±5 V DC, ±6 V DC, ±7 V DC, ±8 V DC, ±9 V DC, ±10 V DC |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 3 kHz |
Excitation | 10 V DC |
Isolation | Yes |
- Transmitter for strain gauge
- Isolated Versions Available
- USB Connectivity for easy calibration
- DAQ Mode with a measuring rate - up to 7500 measurements per second
- 2 Button teach-in for Potentiometer
- Teach-in, allows easy setting of both min. and max. of the measuring range
- Output: 4…20 mA/0…10 V
- Power supply 18…30 VDC
Interface | USB |
Input Type | Strain Gauge |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, 4 - 20 mA, RS-485 |
Excitation | 10 V DC |
Isolation | Yes |