CRSL/C-8, imc CRONOS-SL Chassis Module


- imc CRONOS-SL Differential Amplifier
- 8 Analog Input Channels, Differential
- Voltage, Current, Thermocouple or Pt100 Inputs
- Backplane for Type K Thermo-Socket (option)
- Supports imc Plug & Measure
- Occupies 1 Slot
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage |
Current | |
Thermocouple/RTD | |
Analog Inputs | 8 |
Max Bandwidth | 20 Hz |
Max Sample Rate | 100 Hz |
Resolution | 16-bit |
Min Temperature | -40 °C |
Max Temperature | 85 °C |
IP Rating | IP65 |
CRSL/C-8-D | For imc CRONOS-SL Chassis, 8 Analog Inputs, DSUB Connections |
CRSL/C-8-L | For imc CRONOS-SL Chassis, 8 Analog Inputs, LEMO Connections |
imc Company Brochure Brochure |
imc CRONOS SL, C-8 Datasheet Datasheet |
- Rugged Metal Housing
- 4 Channel input Screw terminals
- Inputs may include Vdc, Vac, ma, RTDs, Thermocouples (TC) and IEPE (ICP) sensors
- Screw Terminals with labels specific to each connector
- Cable compression fitting
- Quick Delivery in North America from Inventory
- imc CRONOS-SL, Portable Chassis
- 2 Module Slots
- 16 Channels
- Onboard Computation & Control Logic
- Onboard Flash Storage
- 100 MBit Ethernet
- Self-Start After Power Failure
- Extremely Robust
Family | imc CRONOS-SL |
Unit Type | Chassis |
Slots | 2 |
Max Throughput | 400 kS/s |
Field Interface | GPS, Sync Pulse |
Max Sample Rate | 100 kHz |
- imc CRONOS-SL Portable Chassis
- 4 Module Slots
- 32 Channels
- Onboard Computation & Control Logic
- Onboard Flash Storage
- 100 MBit Ethernet
- Self-Start After Power Failure
- Extremely Robust
Family | imc CRONOS-SL |
Unit Type | Chassis |
Slots | 4 |
Max Throughput | 400 kS/s |
Field Interface | GPS, Sync Pulse |
Max Sample Rate | 100 kHz |
- Graphical User Interface ease of design capabilities
- Imc Hardware configuration and administration
- 3rd Party Hardware Interface available
- Visualization and Analysis of measured data
- Efficient trigger logic for Automated Data Acquisition & Control
- Real-time analysis and results captured and display
- Automated Test Sequence & Control options
- Complete Real-Time Test Automation
- imc CRONOS-SL Differential Amplifier
- 16 Analog Input Channels, Isolated, Differential
- Voltage, Current or Temperature Inputs
- Ideal for Isolated Measurement of Passive Sensors
- Optimal Suppression of 50 Hz Interference
- Supports imc Plug & Measure
- Occupies 2 Slots
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage, Current, Thermocouple/RTD |
Analog Inputs | 16 |
Max Bandwidth | 1 Hz |
Max Sample Rate | 5 Hz |
- imc CRONOS-SL Bridge Amplifier
- 8 Analog Input Channels
- Voltage, Current, Strain Gauge, Bridge & IEPE/ICP Sensor Inputs
- Signal Bandwidth up to 5 kHz
- Supports imc Plug & Measure
- Occupies 2 Slots
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage, Current, Strain Gauge, ICP |
Analog Inputs | 8 |
Max Bandwidth | 5 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOS-SL Isolated Differential Amplifier
- 8 Analog Input Channels, Isolated
- Voltage, Current, Temperature or ICP-Sensor Inputs
- 16-bit Resolution
- Overvoltage Protection
- Occupies 1 Slot
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage, Current, ICP, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 11 kHz |
Max Sample Rate | 100 kHz |
- imc CRONOScompact Differential Amplifier
- 8 Analog Input Channels, Differential
- Voltage, Current, Thermocouple or Pt100 Inputs
- Backplane for Type K Thermo-Socket (option)
- Supports imc Plug & Measure
- Occupies 1 Slot
- Connectors for V, ma or ICP sensors under "Related" tab
Family | imc CRONOScompact |
Unit Type | Module |
Input Type | Voltage, Current, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 20 Hz |
Max Sample Rate | 100 Hz |
- imc CRONOS-SL All-Purpose Amplifier
- 8 Analog Input Channels
- Voltage, Current, ICP, Bridge, Strain Gauge or Temperature Inputs
- Selectable Quarter Bridge Completion 120 & 350 ohms
- Supports imc Plug & Measure
- Occupies 2 Slots
Family | imc CRONOS-SL |
Unit Type | Module |
Input Type | Voltage, Current, Strain Gauge, ICP, Thermocouple/RTD |
Analog Inputs | 8 |
Max Bandwidth | 48 kHz |
Max Sample Rate | 100 kHz |