HPS464508HF, Composite Top Optima Multi-Axis Force Platform

The HPS464508HF is a high-frequency, composite-top force plate from AMTI’s OPTIMA™ High-Performance Series—delivering unmatched accuracy, responsiveness, and structural efficiency for the most demanding biomechanics and gait analysis environments.
OR6-6-Composite-Top-2048x1390_e6ef0906.jpg
OR6-6-Composite-Top-2048x1390_e6ef0906.jpg
OR6-7-Optima-foot-images-2048x1390_7f3a1914.jpg
OR6-7-Shoes-e1651783744666-2048x1276_f84e6f51.jpg
OPT464508HF, Optima Force Platform
Features:
  • Composite Top Design
  • Highest-density calibration available on the market for exceptional precision
  • Optimized for high-frequency testing in vibration-prone or dynamic environments
  • Multi-axis sensing: Fx, Fy, Fz, Mx, My, Mz
  • Dimensions: 464 mm × 508 mm
  • Capacities: 4448 N and 8896 N (Fz)
  • Compatible with AMTI’s Modular Rail System and OPT-SC amplifier
Manufacturer:  Advanced Mechanical Technology Inc. (AMTI)
Quote
Datasheet
Description
Specifications
Applications
Models & Accessories
Downloads
Similar Products
HPS464508HF - Description

The HPS464508HF (formerly OPT464508HF) is part of AMTI’s High Performance Series and features a composite top design, engineered to reduce structural mass and enhance stiffness. This leads to a more responsive system in high-speed testing scenarios and environments with background vibration.

With a sensing configuration that includes all six load components—Fx, Fy, Fz (forces) and Mx, My, Mz (moments)—this model provides accurate kinetic data for motion and gait analysis. The high-density calibration used in OPTIMA-HPS platforms ensures superior measurement linearity across the full surface.

The Center of Pressure (COP) accuracy is <0.2 mm, making this plate highly suitable for applications where spatial precision is critical, such as pediatric gait studies or balance assessment.

This model supports both USB and analog outputs and integrates with AMTI’s OPT-SC amplifier and Modular Rail System for flexible lab configurations.

HPS464508HF - Specifications
Full Scale (Fz)1000 lbs
2000 lbs
Fz Natural Frequency460 Hz
500 Hz
Non-Linearity± 0.1 % FS
Resolution16-bit
Output± 5 V DC
Dimensions464 x 508 x 83 mm
Weight40 lbs
Top Plate MaterialComposite
InterfaceUSB
Power Supply110 - 240 V AC
Min Temperature-18 °C
Max Temperature50 °C
HPS464508HF - Applications
  • High-speed gait and balance testing

  • Clinical and research biomechanics

  • Pediatric and adult motion analysis

  • Dynamic environments requiring high stiffness and accuracy

HPS464508HF - Models & Accessories
Models
HPS464508HF -1000Fz Range: 1000 lbs, Fz Freq.: 1000 Hz
HPS464508HF -2000Fz Range: 2000 lbs, Fz Freq.: 1000 Hz
OPT464508HF
HPS464508HF - Downloads
HPS464508HF - Similar Products
  • Intuitive and easy to use
  • State-of-the-art signal conditioning
  • Average COP accuracy of just a fraction of a millimeter (typically less than 0.2)
  • Crosstalk values typically ±0.05% of applied load
  • Measurement accuracy typically ±0.1% of applied load
  • Built on OPTIMA-HPS calibration: the highest accuracy available on the market
  • 6-axis force and moment sensing (Fx, Fy, Fz, Mx, My, Mz)
  • Ideal for human movement science, clinical gait, and research-grade biomechanics
Full Scale (Fz)
1000 lbs,
2000 lbs
Fz Natural Frequency
370 Hz,
400 Hz
Non-Linearity
± 0.1 % FS
Resolution
16-bit
Output
± 5 V DC
Dimensions
400 x 600 x 83 mm
  • Intuitive and easy to use
  • State-of-the-art signal conditioning
  • Average COP accuracy of just a fraction of a millimeter (typically less than 0.2)
  • Crosstalk values typically ±0.05% of applied load
  • Lightweight composite top plate improves dynamic response
  • Fx/Fy and Fz natural frequencies elevated for high-speed analysis
  • Calibrated with OPTIMA-HPS high-density process for uniform spatial accuracy
  • Measures six components: Fx, Fy, Fz, Mx, My, Mz
Full Scale (Fz)
1000 lbs,
2000 lbs
Fz Natural Frequency
780 Hz,
830 Hz
Non-Linearity
± 0.1 % FS
Resolution
16-bit
Output
± 5 V DC
Dimensions
400 x 600 x 83 mm
  • Intuitive and easy to use
  • State-of-the-art signal conditioning
  • Average COP accuracy of just a fraction of a millimeter (typically less than 0.2)
  • Industry-standard 464 × 508 mm platform for adult and pediatric applications
  • Available in Standard and High Frequency models for dynamic environments
  • Multi-axis sensing (Fx, Fy, Fz, Mx, My, Mz) with strain gage bridge technology
  • USB or analog output; amplifier and mounting kit included
  • Compatible with AMTI's Modular Rail System
Full Scale (Fz)
1000 lbs,
2000 lbs
Fz Natural Frequency
460 Hz,
500 Hz
Non-Linearity
± 0.1 % FS
Resolution
16-bit
Dimensions
464 x 508 x 83 mm
Weight
62 lbs
  • Composite Top Design for improved dynamic response
  • Optimized for clinical gait, pediatric motion, and biomechanical studies
  • Dimensions: 464 mm × 508 mm
  • Capacities: 4448 N and 8896 N (Fz)
  • Multi-axis sensing: Fx, Fy, Fz, Mx, My, Mz
  • Center of Pressure (COP) accuracy: <0.5 mm
  • USB digital and analog output options
  • Integrated with AMTI's OPT-SC amplifier and Modular Rail System
Full Scale (Fz)
1000 lbs,
2000 lbs,
4000 lbs
Fz Natural Frequency
1000 Hz
Resolution
16-bit
Dimensions
464 x 508 x 83 mm
Weight
40 lbs
Top Plate Material
Composite