SpeedSys T30 Conditioner, 3-channel Speed Monitor, Transmitter & Controller
- Accepts signal inputs from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Six configurable high speed relays (10 ms response time) for multiple speed functions
- Three highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- Three Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
- 2002 SIL2 Protection
- Modbus interface for data stream
- DIN-rail mount with Screw terminal connections
- Configuration software suite, Ethernet TCP/IP for programming & status reading
- Fieldbus Communication, Modbus TCP
Redundant input channels
The SpeedSys T30 connects every common speed sensor with a industry standard output. The 3-channel monitoring and switching device is ideal for speed protection and monitoring on rotating machinery.
System features
- 3 independent channels
- Redundant sensor inputs
- Redundant power supply
- 6 high speed relays
- 3 configurable trip relays (DPST)
- 3 configurable alarm relays (SPST)
- Fast 8 millisec hardware response time (relays)
- Highly accurate analog output signals (4-20 mA)
- Signal filter and line amplifier
- Software-selectable cross-channel connection: Outputs can be programmed to use the sensor signal of other PCBs in the same device.
- Software-programmable voting: Allows programming of various voting structures like 1oo2, 2oo2, 1oo3, 2oo3, 3oo3.
- Reverse rotation: With two sensor signals with a phase difference, the rotational direction of the machine can be determined.
Interface | TCP/IP |
RS-485 | |
Input Type | 20 milli Vrms |
0 - 10 V AC | |
80 Vrms | |
Frequency | |
# of Inputs | 3 |
Output Type | 2 - 10 V DC |
4 - 20 mA | |
Max Bandwidth | 5 kHz |
Excitation | 24 V DC |
Supply Power | 20 - 28 V DC |
The SpeedSys T30 is used as a 2 or 3 channel Monitor, Transmitter and/or Switch Control device for speed conditions on rotating machinery.
Typical applications are:
- Aeroderivatives
- Micro turbines
- Wind turbines
- Gas- and steam turbines
- Hydro turbines
- Compressors
- Expanders
- Marine applications
- Elevators
- General automation
SpeedSys Tx0 series Datasheet Datasheet |
- Accepts 1 signal input from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Two configurable relays (10 ms response time) for multiple speed functions
- One highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- One Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface | TCP/IP, RS-485 |
Input Type | 20 milli Vrms, 0 - 10 V AC, 80 Vrms, Frequency |
# of Inputs | 1 |
Output Type | 2 - 10 V DC, 4 - 20 mA |
Max Bandwidth | 10 kHz |
Excitation | 24 V DC |
- Accepts signal inputs from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Four configurable high speed relays (10 ms response time) for multiple speed functions
- Two highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- Two Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface | TCP/IP, RS-485 |
Input Type | 20 milli Vrms, 0 - 10 V AC, 80 Vrms, Frequency |
# of Inputs | 2 |
Output Type | 2 - 10 V DC, 4 - 20 mA |
Max Bandwidth | 10 kHz |
Excitation | 24 V DC |
- High accuracy speed measurement: 0.002% for limits and 0.1% referenced to 20 mA
- 2 frequency + 2 binary inputs
- 2 current, 4 relay and 2 Open Collector outputs
- Sensor monitoring for all sensor technologies
- Ethernet interface - confi guration via Windows® software
- Extensive parameter and limit setting possibilities
- Programmable logical, diagnostic and measurement functions
- Supply 18..36 VDC or 90..264 VAC
Interface | TCP/IP |
Input Type | Frequency |
# of Inputs | 2 |
Output Type | 0 - 20 mA, 4 - 20 mA |
Isolation | Yes |
Supply Power | 18 - 36 V DC, 90 - 264 V AC |
- High accuracy speed measurement: 0.002% for limits and 0.1% referenced to 20 mA
- 2 frequency + 1 analog + 2 binary inputs
- Direction and creep detection
- Temperature measurement with PT100
- 2 current, 4 relay and 2 Open Collector outputs
- Sensor monitoring for all sensor technologies
- Ethernet interface - confi guration via Windows software
- Extensive parameter and limit setting possibilities
Interface | TCP/IP |
Input Type | 0 - 20 mA, 4 - 20 mA, Frequency, RTD, CANbus |
# of Inputs | 3 |
Output Type | 0 - 20 mA, 4 - 20 mA |
Isolation | Yes |
Supply Power | 18 - 36 V DC, 90 - 264 V AC |
- Accepts 1 signal input from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Two configurable relays (10 ms response time) for multiple speed functions
- One highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- One Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface | TCP/IP, RS-485 |
Input Type | 20 milli Vrms, 0 - 10 V AC, 80 Vrms, Frequency |
# of Inputs | 1 |
Output Type | 2 - 10 V DC, 4 - 20 mA |
Max Bandwidth | 10 kHz |
Excitation | 24 V DC |
- Accepts signal inputs from 3-wire voltage sensors (Hall-effect & proximity),
- Accepts 2-wire voltage signals or digital input signals from encoders.
- Dynamic monitoring, comparing chns, reverse rotation, creep and standstill.
- Input Voltage Ranges from 20 mVrms to 80 Vrms
- Input Frequency capable from 0.025 Hz up to 35 kHz (200kHz for Digital Pulse)
- Four configurable high speed relays (10 ms response time) for multiple speed functions
- Two highly accurate analog outputs (4-20 mA or optional 2 – 10 V)
- Two Frequency Signal Outputs, (open collector, max. 24 V, 100 ma)
Interface | TCP/IP, RS-485 |
Input Type | 20 milli Vrms, 0 - 10 V AC, 80 Vrms, Frequency |
# of Inputs | 2 |
Output Type | 2 - 10 V DC, 4 - 20 mA |
Max Bandwidth | 10 kHz |
Excitation | 24 V DC |