Loading...
A-Tech Instruments Ltd.
Français   |   Welcome. Please Register an Account or Login

T9740, RFO High-Performance Flow tester

With standard flow valves, this unit is ideal for testing volumes up to 10 liters. Low maintenance, stable and noise free.
T9740, RFO High-Performance Flow tester
T9740, RFO High-Performance Flow tester
Features:
  • Latest evolution in continuous capacity measurement instrumentation,
  • Specifically for applications with high variability of flow values and the need for very high adjustment of the pressure, to compensate those different load losses.
  • Multiple Programs for different parts
  • HMI touchscreen controller
  • Multiple Languages, English, French, Spanish, Italian, …
  • Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
  • Data Collection by Serial Number, using a PC or PLC (optional Field buses, Ethernet IP, Modbus)
Manufacturer:  ForTest
Quote
Datasheet
Description
Specifications
Applications
Models & Accessories
Downloads
Related Products
Similar Products
T9740 - Description

The ForTest T9740, with new “RFO” technology, is the latest evolution in continuous capacity measurement instrumentation. Specifically for applications with high variability of flow values and the need for very high adjustment of the pressure, to compensate those different load losses.

Typical applications include leak testing of boiler gas-tight chambers, car, tractor or lorry cabs, chimney flues, etc…where the test pressures requested are very low (0.5…10 mbar) and therefore pressure adjustment must be extremely stable and precise. The new T9740 equipment includes standard flow valves, is ideal for testing volumes up to 10 liters. Low maintenance, stable and noise free.

Advanced interface.

Fortest considers the T9000 series as the most technologically forward of measurement systems, equipped with an advanced interface, useful for analysis and research during the prototyping or pre-series phase, as well as for production line testing.

The big, 7” colour display set in a capacitive glass panel allows total interaction with the internal menus and the main screen. The "smart" testing archive contains daily and monthly analysis functions and those specifically for each test program, to keep the level of quality of your products under control.

Limitless connectivity.

The new T9740 equipment includes ports for the USB slave, RS232, RS485, Can bus and TTY. Assembly may also include an optional Ethernet port and a 26-pole connector with 4 inputs and 8 outputs, which are completely programmable, for interfacing with the external valves, safety barriers, switches, etc...

The front panel has a master USB port assembled on it for connection to a USB key to save the tests conducted, backup/restore parameters and upgrade tool firmware.
The connection to thermal printers, barcode/data-matrix readers and markers takes place automatically using an internal menu.

Top category technology.

Fortest decided not to make compromises when equipping the T9740, assembling the best components currently on the market, such as the piezoelectric electronic regulator which guarantees stable and repetitive adjustment, or the solid-state sensor with a vast reading range. Nor with the specific valves for this model, with a life estimated in the tens of millions of cycles.

All these advantages give never before seen precision performance, stability and accuracy.
The measurement resolution starts at 0.1 cc / min based on the full scale, ranging from 10 to 100 l / min, with maximum pressures of 100 mbar.

Made to measure pneumatic section.

To avoid overheating due to long activation times of the filling circuit, Fortest has designed in particular high capacity pneumatic valves, which not only work in hot temperatures, but also quickly fill the piece being tested, making the T8710 also suitable for testing on parts with significant volumes.
All of the above has been done, while maintaining ForTest's historic reliability.

Technical Specifications

-Dimensions 300x160x650 mm
-Weight 10 Kg
-Electrical Supply 24 VDC, 110 VAC, 230 VAC
-Air tune size: 4x2.7, 6x4, 8x6, 10x8

T9740 - Specifications
TypeMass Flow
# of Channels1
Resolution0.01 sccm/min
Display7" Colour Display
Data StorageUSB
InterfaceRS-232
RS-485
Profinet
EtherCAT
Ethernet TCP/IP
Accuracy0.25% to 0.5%
T9740 - Applications

Aerospace, Automotive, Household Appliances, Electronics, Medical, Alternative Energy, Packaging 

T9740 - Models & Accessories
Accessories
External start button
External start/abort pushbutton
External pushbutton 4 programs selection
Start pedal
Barcode reader
Adhesive label for printer 4500pcs
Aux signals extension cable
Precision micrometer nozzle
Micrometer nozzle
M series manager software
TTY
Serial protocol
PC serial cable owner ---> M Series
External temperature probe
MIXER-07
Software Data Manager
Thermal printer without peel
Adapter cable AUX M Series ---> ET Series
Remote Start / Abort / Good / Reject
Software "Data Manager"
Air filter 5 micron
Electronic pressure Regulator - (STANDARD)
Auto zero primary pressure circuit - (STANDARD)
Waiting Primary pressure reading - (STANDARD)
Secondary Output of Waste (third result)
Leak Analog Output
I/O 24 Vdc expansion signal card
Bi-manual logic Start Input
Ethernet plug/TCP-IP
Active USB port
WI-FI connection
Radio remote control selection Kit
High resolution measure - (STANDARD)
Indirect measure
T9740 - Downloads
T9740 - Related Products
  • Two different testing methods
  • USB Type-B female connector for PC
  • 6 languages (English, Italian, French, German, Spanish, Portuguese)
  • Mechanical Start/Stop button
  • Firmware update via USB stick
  • Password protection
  • 24V I/O (Start,Stop,Test,Good,Reject,4BCD)
  • available measurement units: mbar, bar, psi, mmHg, mmH20, Pa, HPa, cc/min, cc/h, pressure/s , l/h , l/min
Type
Mass Flow,
Pressure Decay
# of Channels
1
Resolution
1 Pa (0.00015 psi)
Display
6.2 in Colour Display
Data Storage
USB
Interface
RS-232,
RS-485,
Profinet,
EtherCAT,
Ethernet TCP/IP
  • Fully automatic test flow adjustment management (8,000 Lt/min)
  • Multiple Programs for different parts
  • HMI touchscreen controller
  • Multiple Languages, English, French, Spanish, Italian…
  • Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
  • Data Collection by Serial Number, using a PC or PLC (optional Field buses, Ethernet IP, Modbus)
Type
Mass Flow,
Pressure Decay
# of Channels
1
Resolution
0.1 Pa (0.000015 psi)
Display
6.5 in Color Display
Data Storage
USB
Interface
RS-232,
RS-485,
Profinet,
EtherCAT,
Ethernet TCP/IP
  • Fully automatic test flow adjustment management (8,000 Lt/min)
  • Multiple Programs for different parts
  • HMI touchscreen controller
  • Multiple Languages, English, French, Spanish, Italian, …
  • Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
  • Data Collection by Serial Number, using a PC or PLC (optional Field buses, Ethernet IP, Modbus)
Type
Mass Flow
# of Channels
1
Resolution
0.01 sccm/min
Data Storage
USB
Interface
RS-232,
RS-485,
Profinet,
EthernetIP,
EtherCAT,
Ethernet TCP/IP
Accuracy
0.5%
  • Multiple Programs for various applications
  • HMI touchscreen controller
  • Multiple Languages, English, French, Spanish, Italian, …
  • Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
  • Data Collection by Serial Number, using a PC or PLC (optional Field buses, Ethernet IP, Modbus)
Type
Mass Flow
# of Channels
1
Resolution
0.01 sccm/min
Display
7" Colour Display
Data Storage
USB
Interface
RS-232,
RS-485,
Profinet,
EtherCAT,
Ethernet TCP/IP
  • Solid state sensor
  • Direct display of the volumetric leak
  • Continuous injection of test air
  • High capacity pneumatic valves
  • Heat-proof pneumatic valves
  • Low maintenance
  • Measurement up to 1,000 cc/min
Type
Mass Flow
Resolution
1 Pa (0.00015 psi)
Data Storage
USB
Interface
RS-232,
RS-485
Accuracy
0.5%
T9740 - Similar Products
  • Multiple Programs for various applications
  • HMI touchscreen controller
  • Multiple Languages, English, French, Spanish, Italian, …
  • Sequence – Fill to Test Pressure, Stabilize, Measure Absolute Pressure Decay, calibrated leak rate
  • Data Collection by Serial Number, using a PC or PLC (optional Field buses, Ethernet IP, Modbus)
Type
Mass Flow
# of Channels
1
Resolution
0.01 sccm/min
Display
7" Colour Display
Data Storage
USB
Interface
RS-232,
RS-485,
Profinet,
EtherCAT,
Ethernet TCP/IP
Products    |    Applications    |    Services    |    Partners    |    About Us    |    Contact Us