microCAT3, 64 Channel EtherCAT Pressure Scanner





- EtherCAT interface for high-speed data transmission.
- Dual 24-bit ADCs for unparalleled accuracy and thermal compensation.
- Capability of handling both differential and absolute measurements.
- Electrically driven purge valve for enhanced operational consistency.
- Quick disconnect option for flexible tubing management.
Type | Scanner |
- Pneumatic Intelligent Differential Pressure Scanner
- Dry Noncorrosive Gases
- Proof Pressure 3 Times Rated Pressure (< 15 psi)
- Proof Pressure 2 Times Rated Pressure (15 - 100 psi)
- Proof Pressure 1.5 Times Rated Pressure (> 100 psi)
- 16 Pressure Sensors from 10WC up to 850 psi
- 0.063" Tubulation & Compression Fittings Available
Type | Scanner |
# of Channels | 16 |
Operational Mode | Differential |
Full Scale | 1 psi, 2.5 psi, 5 psi, 10 psi, 15 psi, 30 psi, 45 psi, 100 psi, 250 psi, 500 psi, 750 psi, 850 psi |
Output | Ethernet |
Precision | ±0.05 % FS |
- ±0.05% Accuracy
- 100 Hz EU Throughput
- Auto-negotiating 10/100/1G Base T Ethernet - TCP and UDP Protocol
- Pressure Ranges up to 850 psid (5860 kPa)
- Rezero, Purge and Leak Check Functionality
- Triple Scan List Capability
- Hardware and Software Initiated Data Acquisition
- Typical Applications Turbine Engine Research & Turbomachinery Test Stands
Type | Scanner |
# of Scanners | 8 |
# of Channels | 16 |
Operational Mode | Absolute, Differential |
Full Scale | 1 psi, 2.5 psi, 5 psi, 10 psi, 15 psi, 30 psi, 45 psi, 100 psi, 250 psi, 500 psi, 750 psi, 850 psi |
Output | Ethernet |
- ±0.05% FS System Accuracy
- EU throughput Rates of 100 Hz
- IEEE 1588-2008 PTPv2 & NTP Disciplined Clock
- Scheduled Start of Scanning
- IPv4 and IPv6 Compatible
- Removable Memory
- Hardware Compatible with 98RKand 98RK-1
- Software Compatible with 9816
Type | Scanner |
# of Channels | 16 |
Operational Mode | Differential |
Full Scale | 0.5 psi, 0.7 psi, 1 psi, 2.5 psi, 5 psi, 10 psi, 15 psi, 30 psi, 45 psi, 100 psi, 250 psi, 500 psi, 750 psi, 850 psi |
Min Temperature | 0 °C |
Max Temperature | 50 °C |
- Wind-tunnel Pressure Scanning System
- ESP Pressure Scanner Compatible
- Up to +/- 0.03% Accuracy
- Up to 2000 Hz/port EU Data Throughput
- DTC Digital Temperature Compensation Technology
- Miniature Scanner Digitizing Interface
- On Line Calibration
- On Line Verification
Type | Scanner |
Interface | ESP, ESP-DTC |
# of Scanners | 8 |
Output | Ethernet |
Min Temperature | -25 °C |
Max Temperature | 100 °C |
- Differential or Absolute compensated engineering unit pressure data
- Precision measurements are provided by dual 24-bit ADC’s for pressure & temperature
- Electrically Driven Valve (optional) gives the scanner a purge and re-zero facility.
- Precise Temperature measurement compensates for thermal effects on the Pressure Measurements.
- Pressure Ranges from 4”WC up to 45 psid and 16 to 58 psia
Type | Scanner |
# of Channels | 64 |
Operational Mode | Absolute, Differential |
Full Scale | 0.5 psi, 50 psi |
Output | Ethernet, CANOpen |
Precision | ±0.03 % FS, ±0.06 % FS |