LT-FR, 4-20 mA & Serial Data Transmitter for Duty Cycle and PWM Signals

Measures ON/OFF duty cycle or PWM signals with outstanding precision. DIN rail mounted, digitally programmable.
LT-FR, 4-20 mA & Serial Data Transmitter for Duty Cycle and PWM Signals
LT-FR, 4-20 mA & Serial Data Transmitter for Duty Cycle and PWM Signals
Features:
  • 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V transmitter output, 16 bits, isolated.
  • RS232 or RS485 serial data output, Modbus or Laurel ASCII protocol, isolated.
  • Dual 120 mA solid-state relays for alarm or control, isolated.
  • Measures duty cycle with selectable resolution (1%, 0.1%, or 0.01%).
  • Supports frequencies from 0.005 Hz to 10 kHz.
  • Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac.
  • Analog output resolution 0.0015% of span (16 bits), accuracy ±0.02% of span 5V, 10V or 24V dc transducer excitation output, isolated
Manufacturer:  Laurel Electronics Inc.
Quote
Datasheet
Specifications
Downloads
Similar Products
LT-FR - Specifications
InterfaceRS-232
RS-485
Input TypeAC voltage
Output Type0 - 10 V DC
±10 V DC
0 - 20 mA
4 - 20 mA
IsolationYes
Min Temperature0°C
Max Temperature55°C
LT-FR - Downloads
LT-FR - Similar Products
  • 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V transmitter output, 16 bits, isolated.
  • RS232 or RS485 serial data output, Modbus or Laurel ASCII protocol, isolated.
  • Dual 120 mA solid-state relays for alarm or control, isolated.
  • True AC RMS measurement in one 50/60 Hz AC line cycle.
  • Voltage ranges: ±0.2V, ±2V, ±20V, ±200V, ±300V, ±600V.
  • Current ranges: ±2 mA, ±20 mA, ±200 mA, ±5A.
  • Input ranges are user-selectable and factory-calibrated.
  • AC or DC coupling for signals from DC to 5 kHz.
Interface
RS-232,
RS-485
Input Type
0 - 5 A AC,
AC voltage
Output Type
0 - 10 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Isolation
Yes
Min Temperature
0°C
Max Temperature
55°C
  • 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V transmitter output, 16 bits, isolated.
  • RS232 or RS485 serial data output, Modbus or Laurel ASCII protocol, isolated.
  • Dual 120 mA solid-state relays for alarm or control, isolated.
  • Arithmetic functions: A+B, A-B, AxB, A/B, A/B-1.
  • Input frequencies: 0.005 Hz to 1 MHz.
  • Inputs from NPN or PNP proximity switches, contact closures, digital logic,
  • magnetic pickups down to 12 mV, or AC inputs up to 250 Vac
  • Analog output resolution 0.0015% of span (16 bits), accuracy ±0.02% of span
Interface
RS-232,
RS-485
Input Type
Frequency,
AC voltage
Output Type
0 - 10 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Excitation
5 V DC,
10 V DC,
24 V DC
Isolation
Yes
Min Temperature
0°C
  • 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V transmitter output, 16 bits, isolated.
  • RS232 or RS485 serial data output, Modbus or Laurel ASCII protocol, isolated.
  • Dual 120 mA solid-state relays for alarm or control, isolated.
  • Measures time from 0.2 µs to 999,999 hours.
  • Tracks single event or accumulated time for multiple events.
  • Supports inputs from NPN/PNP switches, logic, and magnetic pickups.
Interface
RS-232,
RS-485
Input Type
Frequency
Output Type
0 - 10 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Excitation
5 V DC,
10 V DC,
24 V DC
Isolation
Yes
Min Temperature
0°C
  • 4-20 mA, 0-20 mA, 0-10V or -10V to +10V transmitter output, 16 bits, isolated
  • RS232 or RS485 serial data output, Modbus or Laurel ASCII protocol, isolated
  • Dual 120 mA solid state relays for alarm or control, isolated
  • Accepts low-level differential or single-ended 5V logic level signals from shaft encoders, linear encoders, incremental encoders or optical encoders
  • Programmable for position, angle or rate
  • Quadrature count x1, x2 or x4 with combined pulse rate to 250 kHz
  • Zero channel input
  • Analog output resolution 0.0015% of span (16 bits), accuracy ±0.02% of span
Interface
RS-232,
RS-485
Input Type
Frequency,
Counter
Output Type
0 - 10 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Min Temperature
0°C
Max Temperature
55°C
  • 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V transmitter output, 16 bits, isolated.
  • RS232 or RS485 serial data output, Modbus or Laurel ASCII protocol, isolated.
  • Dual 120 mA solid-state relays for alarm or control, isolated.
  • Factory calibrated for 100Ω platinum (Pt100), 10Ω copper (Cu10), and 120Ω nickel (Ni120) RTDs.
  • Supports 2, 3, or 4-wire RTD connections with lead resistance compensation.
  • User-selectable input span from the full RTD range to as narrow as 15.0°.
  • Analog output resolution: 0.0015% of span; accuracy: ±0.02% of span.
Interface
RS-232,
RS-485
Input Type
RTD
Output Type
0 - 10 V DC,
±10 V DC,
0 - 20 mA,
4 - 20 mA
Min Temperature
-40°C,
0°C
Max Temperature
55°C,
70°C