9307 DigiForce, Multi channel Press Force Monitor & Functional Tester
- Comprehensive process monitoring delivered by innovative evaluation elements window, thresholds, trapeziums, envelopes and mathematical operations
- High measurement accuracy 0.05 % possible at 10 KHz sampling rate
- Flexible process integration thanks to a range of
- Fieldbus interfaces
- Simultaneous monitoring of two synchronous processes
- Ethernet, USB, RS232 as standard
- Up to 128 measurement programs for a large variety of parts
- Transfer of process, component and worker data
- Intelligent signal sampling using a combination of ∆t, ∆X, ∆Y
- Independent and variable start/stop logic
- Convenient configuration screens
- DigiControl PC software with powerful data-logging function for process data
The DIGIFORCE® 9307 monitors processes in which precisely defined functional relationships between two or more measured quantities need to be demonstrated. These measured quantities are recorded synchronously during the manufacturing process or subsequent functional testing to produce a measurement curve, which is then assessed using graphical and mathematical evaluation techniques.
After internal evaluation, the measurement curve and computed evaluation results are visualized on the color display and are also output at the external control interfaces. The processes in the controller are optimized by a powerful real-time operating system to achieve an extremely fast evaluation cycle: it typically takes just 20 ms to deliver the global OK or NOK evaluation result, which can then be analyzed by the higher-level controller.
In addition to the traditional evaluation windows with defined entry and exit sides, the DIGIFORCE® 9307 also offers thresholds, trapeziums of type X or Y and envelopes as graphical evaluation elements. Individual evaluation results from the graphical tools can then be combined by mathematical operations to provide even more analysis flexibility for a huge range of signal curves.
DIGIFORCE® has a wide range of process control applications, including monitoring processes such as joining, riveting or caulking, or checking torque curves, for instance for hinges or high-quality rotary controls. Even complex signal/time curves (e.g. pressure curves, leaks etc.) can be monitored using the large choice of evaluation techniques.
Simultaneous recording of up to two Y variables (Y1 and Y2) with respect to a common X variable allows many applications to Compatible sensors use one DIGIFORCE® controller to monitor two synchronous
processes.
Alternatively, this feature can be used to evaluate an application with three process variables, for instance the force/displacement curve and associated current consumption of a lifting electromagnet.
While DIGIFORCE® is used in many automated production areas, it is equally at home in the manual workstation, for instance to monitor force/displacement when using hand presses for assembly or for random spot-checking in goods inwards.
Input Type | DC Voltage |
Potentiometer | |
Strain Gauge | |
ICP | |
Resistance | |
Encoder | |
SSI | |
# of Inputs | 2 |
3 | |
Max Sample Rate | 10 kHz |
Evaluation | Threshold |
Envelopes | |
Windows | |
Trapezium | |
Math Operations | |
Interface | Digital I/O |
Profibus | |
Profinet | |
Ethernet/IP | |
EtherCAT | |
Communication | Ethernet |
USB | |
RS-232 |
- Pressing Applications (Bushing, Pins, Dowel)
- Door Hinge Range of Motion
- Brake, Accelerator and Clutch Pedal effort and electrical characteristics
- Electrical Switch Testing (Linear and Rotary)
- Plastic Housing Assembly
- Seat Slide Functional Testing
- Motor Testing (Torque vs. Angle vs. Current)
- Any Application where there are repeatable relationships between 2 or 3 signals
Brake, Accelerator and Clutch Pedal effort - Force versus Displacement / Angle
Slow motion video. The Test Cycle Time can be reduced to >5 seconds.
9307-V0000 | Graphical Display; Std Inputs mV & Vdc; Digital I/O & Ethernet TCP/IP |
9307-V0100 | Graphical Display; Std Inputs Piezo Option, mV & Vdc; Digital I/O & Ethernet TCP/IP |
9307-V0200 | Graphical Display; Std Inputs Combined Analog/ Encoder + Resistance Measurement; Digital I/O & Ethernet TCP/IP |
9307-V0001 | Graphical Display; Std Inputs mV & Vdc; Digital I/O, Ethernet TCP/IP & EtherCAT |
9307-V0002 | Graphical Display; Std Inputs mV & Vdc; Digital I/O, Ethernet TCP/IP & Profibus |
9307-V0003 | Graphical Display; Std Inputs mV & Vdc; Digital I/O, Ethernet TCP/IP & Profinet |
9307-V0004 | Graphical Display; Std Inputs mV & Vdc; Digital I/O, Ethernet TCP/IP & Ethernet/IP |
9307-V0101 | Graphical Display; Std Inputs Piezo Option, mV & Vdc; Digital I/O, Ethernet TCP/IP & EtherCAT |
9307-V0102 | Graphical Display; Std Inputs Piezo Option, mV & Vdc; Digital I/O, Ethernet TCP/IP & Profibus |
9307-V0103 | Graphical Display; Std Inputs Piezo Option, mV & Vdc; Digital I/O, Ethernet TCP/IP & Profinet |
9307-V0104 | Graphical Display; Std Inputs Piezo Option, mV & Vdc; Digital I/O, Ethernet TCP/IP & Ethernet/IP |
9307-V0201 | Graphical Display; Std Inputs Combined Analog/ Encoder + Resistance Measurement; Digital I/O & Ethernet TCP/IP & EtherCAT |
9307-V0202 | Graphical Display; Std Inputs Combined Analog/ Encoder + Resistance Measurement; Digital I/O & Ethernet TCP/IP & Profibus |
9307-V0203 | Graphical Display; Std Inputs Combined Analog/ Encoder + Resistance Measurement; Digital I/O & Ethernet TCP/IP & Profinet |
9307-V0204 | Graphical Display; Std Inputs Combined Analog/ Encoder + Resistance Measurement; Digital I/O & Ethernet TCP/IP & Ethernet/IP |
9307-VX0X0 CAD Drawing Drawings |
9307-VX2X0 CAD Drawing Drawings |
9307-VX2X1 CAD Drawing Drawings |
9307-VX2X2 CAD Drawing Drawings |
9307-VX2X3 CAD Drawing Drawings |
9307-VX2X4 CAD Drawing Drawings |
9307 Digiforce Controller Datasheet |
9307 DigiForce Process and Control Overview Brochure |
Precision Torque Monitoring with 9307 and 8661 Brochure |
Digiforce 9307, 9311 Comparison Brochure |
9307-VX0X0 CAD Drawing Drawings |
9307-VX2X0 CAD Drawing Drawings |
9307-VX2X1 CAD Drawing Drawings |
9307-VX2X2 CAD Drawing Drawings |
9307-VX2X3 CAD Drawing Drawings |
9307-VX2X4 CAD Drawing Drawings |
- Tension & Compression
- Accuracy: < ±0.25% F.S.
- Accuracy: Range ≤ 5 N: ±0.1% F.S. (Option)
- Outer Diameter: 54.5mm - 155.0mm
- Height: 16.0mm - 50.0mm
- Overload Protection up to 20 kN (Option)
- Connection: 2m Integral Cable
- Stainless Steel
Type | Pancake |
Application | Tension & Compression |
Full Scale | 112 lbs, 220 lbs, 450 lbs, 1120 lbs, 2200 lbs, 4500 lbs, 11200 lbs, 22000 lbs, 45000 lbs |
Output | 1.5 mV/V |
Precision | ±0.1 % FS, ±0.25 % FS |
Excitation | 10 V DC, 10 V AC |
- Potentiometer
- Rectangular Profile Housing
- Anodized Aluminum Housing
- Connection: 1.0m Integral Cable
- Duration: 10^8 Operations
- Displacement Speed: up to 10m/s
Type | Potentiometer |
Full Scale | 25 mm [0.984"], 50 mm, 75 mm, 100 mm, 150 mm |
Output | Potentiometric |
Non-Linearity | ±0.05 % FS, ±0.10 % FS, ±0.20 % FS |
Resolution | 0.01 mm |
Excitation | 0 - 25 V DC, 0 - 60 V DC |
- Potentiometer
- Rectangular Profile Housing
- Anodized Aluminium Housing
- Connection: 5-pin 9991 Plug Connector
- Durability: 10^8 Operations
Type | Potentiometer |
Full Scale | 10 mm, 25 mm [0.984"], 50 mm, 100 mm, 125 mm, 150 mm |
Output | Potentiometric |
Non-Linearity | ±0.05 % FS, ±0.10 % FS, ±0.20 % FS, ±0.30 % FS |
Resolution | 0.01 mm |
Excitation | 0 - 14 V DC, 0 - 25 V DC, 0 - 50 V DC |
- Multiple Device Curve Display, 1, 2, 4 & 8 devices
- Database supported, for SQL access
- Data Storage to csv file format available
- Network capable for remote data review