24508, Digital Megohmmeter


- Resistance measurement range from 50 kΩ ... 10 TΩ
- Current measurement range 10 pA - 10 mA
- Automatic / manual switch of measurement range
- Test voltage 45 V, 100 V, 250 V, 500 V
- Limit value indicator
- RS232 interface (USB and Ethernet option)
The device has an easy-to-use structure in a sturdy metal housing. Easy access to the interior components allows an optimal service.
The measurement range stretches from 50 kΩ up to 10 TΩ resp. 9 pA up to 10 mA with a test voltage of 45 V, 100 V, 250 V and 500 V. The configuration of the device is done via
the two line LCD display with the help of the simple menu structure. It goes without saying that all confi gurations can also be effected the RS232 interface. The connections for the potential-free limit output as well as the external measurement start / stop are located on the backside.
Range | 1 MΩ |
10 MΩ | |
100 MΩ | |
1 GΩ | |
10 GΩ | |
100 GΩ | |
1 TΩ | |
10 TΩ | |
100 TΩ | |
Error | ≤ 1 % |
≤ 5 % | |
≤ 10 % | |
Interface | RS-232 |
USB | |
Ethernet | |
Supply | 230 V AC |
With a test voltage of 45 V, 100 V, 250 V and 500 V the device fulfills most test specifications such as e.g. DIN 51953, 53482 and 54345.
The guard switching allows single resistance measurements in a triangle wiring. This could be e.g. a two line cable with common shield or the measurement of insulating materials on a guarding measurement cell.
The selection of the measurement range is done manually or automatically. Fast subsequent measurements can be realized by the internal limit value indicator. When the measured value exceeds the limit the limit value indicator switches and activates a potential-free relay output. The megohmmeter is the right instrument for use in laboratory as well as industrial applications.
24508 - Digital Megohmmeter Datasheet |
24508-Z001, Measurement Leads Brochure |
2408-Z004, Guard ring measurement cell Brochure |
24508-Z005, Guard ring measurement cell Brochure |
2408-Z006, Guard ring measuring electrode Brochure |
2408-Z011, Electrode Brochure |
- Resistance range 1 kΩ ... 100 TΩ
- Current range 0.1 pA ... 1 mA
- Automatic range selection
- Test voltage selectable from 1 V ... 1000 V
- Limit indicator
- Measurement results storable on external USB flash drive
- RS232 interface (IEEE488, USB and Ethernet optional)
Range | 1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ, 10 TΩ, 100 TΩ |
Error | ≤ 1 % , ≤ 5 %, ≤ 10 % |
Interface | RS-232, USB, Ethernet, IEEE 488 |
Supply | 110 V AC, 230 V AC |