DSCA33, RMS Input Signal Conditioner DIN Rail Modules
- True RMS Input Module
- 1500 V Transformer Isolation
- Standard Operation with Frequencies of 45Hz to 1000Hz
- Extended Range Operation to 20kHz
- Accuracy: ± 0.25%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Overload Protected to 480V (Peak AC & DC) Continuous
Input Type | 0 - 100 mV AC |
0 - 1 V AC | |
0 - 10 V AC | |
0 - 150 V AC | |
0 - 300 V AC | |
0 - 1 A AC | |
0 - 5 A AC | |
# of Inputs | 1 |
Output Type | 0 - 5 V DC |
0 - 10 V DC | |
0 - 1 mA | |
0 - 20 mA | |
4 - 20 mA | |
Isolation | Yes |
Supply Power | 19 - 29 V DC |
DSCA33-01 | 0-100 mV Input, 0-10 V DC Output |
DSCA33-02 | 0-1 V Input, 0-10 V DC Output |
DSCA33-03 | 0-10 V Input, 0-10 V DC Output |
DSCA33-04 | 0-150 V Input, 0-10 V DC Output |
DSCA33-05 | 0-300 V Input, 0-10 V DC Output |
DSCA33-06 | 0-1 A Input, 0-10 V DC Output |
DSCA33-07 | 0-5 A Input, 0-10 V DC Output |
DSCA33-01A | 0-100 mV Input, 0-5 V DC Output |
DSCA33-02A | 0-1 V Input, 0-5 V DC Output |
DSCA33-03A | 0-10 V Input, 0-5 V DC Output |
DSCA33-04A | 0-150 V Input, 0-5 V DC Output |
DSCA33-05A | 0-300 V Input, 0-5 V DC Output |
DSCA33-06A | 0-1 A Input, 0-5 V DC Output |
DSCA33-07A | 0-5 A Input, 0-5 V DC Output |
DSCA33-01B | 0-100 mV Input, 0-1 mA Output |
DSCA33-02B | 0-1 V Input, 0-1 mA Output |
DSCA33-03B | 0-10 V Input, 0-1 mA Output |
DSCA33-04B | 0-150 V Input, 0-1 mA Output |
DSCA33-05B | 0-300 V Input, 0-1 mA Output |
DSCA33-06B | 0-1 A Input, 0-1 mA Output |
DSCA33-07B | 0-5 A Input, 0-1 mA Output |
DSCA33-01C | 0-100 mV Input, 4-20 mA Output |
DSCA33-02C | 0-1 V Input, 4-20 mA Output |
DSCA33-03C | 0-10 V Input, 4-20 mA Output |
DSCA33-04C | 0-150 V Input, 4-20 mA Output |
DSCA33-05C | 0-300 V Input, 4-20 mA Output |
DSCA33-06C | 0-1 A Input, 4-20 mA Output |
DSCA33-07C | 0-5 A Input, 4-20 mA Output |
DSCA33-01E | 0-100 mV Input, 0-20 mA Output |
DSCA33-02E | 0-1 V Input, 0-20 mA Output |
DSCA33-03E | 0-10 V Input, 0-20 mA Output |
DSCA33-04E | 0-150 V Input, 0-20 mA Output |
DSCA33-05E | 0-300 V Input, 0-20 mA Output |
DSCA33-06E | 0-1 A Input, 0-20 mA Output |
DSCA33-07E | 0-5 A Input, 0-20 mA Output |
DSCA33 V2 Datasheet |
DSCA33 Datasheet |
DSCA Series Datasheet |
DSCA Dimensions Drawings |
DSCA Calibration Procedure App Note |
AN101 RMS_Voltage_Current App Note |
AN105 Resistance Temperature Detector V2 App Note |
AN121 RiseTime vs BW App Note |
AN126 Tuning_Surge_Tank_Level_Control_Loops App Note |
AN128 RMS Revisited App Note |
AN129 Harmonics and utility costs App Note |
AN801 DSCA Calibration Procedure App Note |
Hysteresis Specifications Tech Note |
Faraday's Law of Induction Tech Note |
Data Acquisition Systems Accessories Tech Note |
Signal Conditioner Surge Withstand Capability Tech Note |
Signal-to-Noise Ratio, SNR Tech Note |
Signal Conditioning Measured vs Combinational Error Tech Note |
When Good Grounds Go Bad Tech Note |
Sample Test Report Tech Note |
Why Isolation (White Paper) Tech Note |
- Programmable Isolated Transmitters
- AC Voltmeter and Ammeter
- AC Network Analyser
- Teach- In, Digital Filter, Tare
- Output: 0/4...20 mA/0...5 mA/0...2/5/10 V/10V
- Power Supply 10...30 V AC/DC
- Option: Comparators, Data Output
- Isolated
Interface | USB |
Input Type | 0 - 60 mV AC, 0 - 300 mV AC, 0 - 10 V AC, 0 - 120 V AC, 0 - 250 V AC, 0 - 450 V AC, 0 - 1 A AC, 0 - 5 A AC |
# of Inputs | 1 |
Output Type | 0 - 2 V DC, 0 - 5 V DC, 0 - 10 V DC, ±10 V DC, 0 - 5 mA, 0 - 20 mA, 4 - 20 mA, RS-485 |
Isolation | Yes |
Supply Power | 10 - 30 V DC, 10 - 30 V AC |
- AC Voltmeter and Ammeter
- Transmitters have galvanic separation with isolation voltage of 600 V
- Accuracy: ±0.3 % of range
- 35 mm wide DIN Rail Mount
- Rating: IP 20
Input Type | 0 - 450 V AC, 0 - 5 A AC |
# of Inputs | 1 |
Output Type | 0 - 2 V DC, 0 - 5 V DC, 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA, ±20 mA |
Excitation | 5 - 24 V DC |
Isolation | Yes |
Supply Power | 10 - 30 V DC, 10 - 30 V AC, 80 - 250 V AC |
- Strain Gauge & Potentiometer Input Amplifier
- 50 V Continuous Isolation
- Accuracy: ± 0.05%
- DIN Rail Mounted
- In-Line Amplifier (Option)
- Aluminum Housing
- Protection Class: IP40
Input Type | 0 - 10 mV DC, 0 - 100 mV DC, 0 - 1 V DC, 0 - 10 V DC, ±10 V DC, Potentiometer, Strain Gauge |
# of Inputs | 1 |
Output Type | ±5 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 1 kHz, 4 kHz |
Excitation | 2.5 V DC, 5 V DC, 10 V DC |
Isolation | Yes |
- Strain Gauge Input Module
- 1500 V Transformer Isolation
- True 3-Way Isolation
- Accuracy: ± 0.03%
- DIN Rail Mounted Module
- ANSI/IEEE C37.90.1 Transient Protection
- Input Protected to 240 V AC Continuous
Input Type | Strain Gauge |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, ±10 V DC, 0 - 20 mA, 4 - 20 mA |
Max Bandwidth | 3 kHz |
Excitation | 3.33 V DC, 10 V DC |
Isolation | Yes |
- DIN Rail mount, LVDT Amplifier
- Compatible with any standard RDP LVDT (without integral electronics)
- Compatible with LIN & PY When fitted with two 1k Ohm bridge completion resistors (Does not provide analogue voltage linearisation for PY)
- Compatible with most LVDTs from any manufacturer
- Screw terminal connections
- Simple controls for gain and zero adjustment
- Input zero switch
- Signal overload indicator
Input Type | LVDT |
# of Inputs | 1 |
Output Type | 0 - 10 V DC, ±10 V DC, 4 - 20 mA |
Max Bandwidth | 250 Hz |
Excitation | 1 V AC, 3 V AC |
Isolation | Yes |