VM-OCT+, Acoustic Measurement & Analysis Software

Calculation of overall values within a certain frequency range and frequency analysis of amplitudes at discrete frequencies vibrations can also be analyzed in defined frequency intervals, octave bands or fractions of them.
VM-OCT+, Acoustic Measurement & Analysis Software
VM-OCT+, Acoustic Measurement & Analysis Software
VM-OCT Frequency Display
VM-OCT selection
VM-OCT selection
VM-OCT criteria
Features:
  • Corner Frequencies of an octave band have always a ratio of 2:1
  • Octave analysis can be performed with logarithmic frequency scale.
  • Octave band analysis, a mix of overall values and frequency analysis
  • Acoustic measurements with frequency range of 16 .. 16000 Hz is used
  • Octaves and fractions of 1/3 and 1/6 octaves are analyzed.
  • Vibration monitoring of very sensitive equipment, with 1/3 octave bands
  • Octave Filters in compliance with EN 61260
Manufacturer:  MMF
Quote
Datasheet
Applications
Downloads
Related Products
VM-OCT+ - Applications
In addition to the calculation of overall values within a certain frequency range and frequency analysis of amplitudes at discrete frequencies vibrations can also be analyzed in defined frequency intervals, so called octave bands or fractions of them. Octave analysis is typically performed with logarithmic frequency scale. The corner frequencies of an octave band have always a ratio of 2:1. Hence with a logarithmic frequency axis octave bands appear with fixed width. 
Octave band analysis is a mix of overall values and frequency analysis. It shows the vibration values of different frequency intervals at a glance.
There are mainly two fields of application for this type of measurement:
- Acoustic measurements: The frequency range of 16 .. 16000 Hz is used. Octaves and fractions of 1/3 and 1/6 octaves are analyzed.
- Vibration monitoring of very sensitive equipment: Mainly 1/3 octave bands are measured. The frequency range of 1 (4) .. 80 Hz is commonly used in the semiconductor industry for monitoring the production environment.
 
VM-OCT can be used for the measurement of so called Vibration Criteria (VC lines), Nano lines and for acoustic measurements with octave, 1/3 octave and 1/6 octave bands.
VibroMetra uses octave filters in compliance with EN 61260.
VM-OCT+ - Downloads
VM-OCT+ - Related Products
  • High dynamic range: 0.1 to 40,000 Hz
  • A/D resolution: 24 bit
  • Input Ranges: ±8000 mV, ±800 mV, ±80 mV
  • TEDS: to IEEE 1451.4 standard
  • Convenient calibration with sensor database
  • Digital triggers: 2 at 0 .. 24 V, threshold: 1.5 V
Input Type
Voltage
Analog Inputs
2
Digital Inputs
2